OTR and OVR: two figures, two questions
The OTR (Oxygen Transmission Rate) answers the question “how much oxygen gets through?”. It is the closure’s permeability, in milligrams per year (mg/year). For a batch, an average value is given.
But an average does not tell you whether the closures in the batch perform consistently: two batches can have the same average and still let different amounts of oxygen through from one closure to the next.
The OVR (Oxygen Variation Rate) answers the second question: “how consistent?”. It measures, as a percentage, how far the permeability of closures from the same batch deviates from the average. The lower the OVR, the more uniform the permeability between closures.
How do we measure permeability?
To know a closure’s permeability, you have to measure it. Since 2007, our Oenology team has been developing a method to do so, based on non-invasive, luminescence-based oxygen measurement with our NomaSense O₂ tool.
Key steps of the measurement:
- A nitrogen-flushed bottle. An empty, clear bottle, flushed with nitrogen, is sealed with the closure being tested.
- A sensor read through the glass. A sensor glued inside the bottle measures the oxygen coming in through the closure, twice a day for 14 days.
- A mathematical model. Using these 14 days of measurements, it calculates, among other things, the closure’s permeability in mg/year.
- 20 closures per batch. The operation is repeated on 20 closures from the same batch, which makes it possible to calculate the OTR and the OVR.
How to read the OVR
You don’t need to do the maths to read the OVR. We measure the 20 closures in a batch, calculate their average, then look at how far each closure deviates from it: the larger the deviations from the average, the higher the OVR.
Take two batches with the same average permeability, 0.5 mg/year (illustrative example):
- Consistent batch, OVR 12%. All 20 closures stay close to the average.
- Inconsistent batch, OVR 53%. The most permeable closure lets through more than twice the average, the least permeable barely half.
For the curious: the OVR is a coefficient of variation, i.e. the standard deviation of the 20 values divided by their average, expressed as a percentage.
What 880 closures reveal
We measured 44 batches of 20 closures: 10 batches of NOMACORC closures and 10 batches of SÜBR closures from our plants, plus 19 batches of micro-agglomerated corks and 5 batches of natural corks sourced on the European market in 2025-2026 from the largest suppliers, among the least permeable ranges intended for wines for ageing.
Here are the average OVRs by category:
- NOMACORC: 6%, highly consistent (all batches between 4 and 8%).
- SÜBR: 11%, consistent (all batches between 7 and 14%).
- Micro-agglomerates: 39%, low consistency. This average hides wide differences: depending on the batch, from 15% to over 100%.
- 1-piece natural: 115%, highly inconsistent (all batches above 100%).
The differences follow the manufacturing process. Extrusion, the continuous process used for NOMACORC and SÜBR, ensures the highest production consistency. Micro-agglomerates are moulded, and their OVR varies widely from batch to batch. Natural corks, punched from cork bark, are heterogeneous by nature, as documented in the scientific literature.
What this means for you
The OVR now appears on NOMACORC and SÜBR product sheets. To choose a closure, two figures therefore matter: the OTR, to know how much oxygen gets through, and the OVR, to know whether the closures in a batch let through similar amounts.